Page 111 - Equipment Import Regulations of Viet Nam for K-V Investment Promotion
P. 111

Annex III. Inspection Procedures Under Decision 18


                      V_L I_L cos φ) And the rate of energy consumption is based on power consumption (ther-
                      mal losses) divided by min. operation power requirement (min. design consumption level).
                      Generally, power factor (φ) is 0.95 which is applied for three-phase voltage use.



                      (Actual Consumption/Design Consumption-1) * 100


                      - For single-phase voltage use



                      Power consumption (thermal losses) is calculated using min. operating power minus mul-
                      tiplication of actual measured amperage & voltage for each equipment. (P_1  = VI cos φ)
                      And the rate of energy consumption is based on power consumption (thermal losses) divid-
                      ed  by  min.  operation  power  requirement  (min.  design  consumption  level).  Generally,

                      power factor (φ) is 1.0 which is applied for single-phase voltage use.


                      * For unit conversion (KW-> KVA), power factor shall be applied for calculation (kW/φ

                      = kVA)


                      * Calibration certificate of measuring instrument shall be traced to inspection certificate.


                  ˞ In case of Raw Material Consumption



                        The difference between designed and actual input of raw material is calculated for raw material
                        consumption. And the rate of raw material consumption is based on raw material

                        consumption divided by design input of raw material.


                        (Actual Input/Design Input-1) * 100





                 (6) Confirm whether technologies of the technological line must not be on the List of technologies
                   prohibited or restricted from transferring promulgated under the Vietnamese Government’s
                   Decree No. 76/2018/ND-CP dated May 15, 2018. At the commencement of the inspection,

                    Inspector should notify to Enterprise that if Enterprise have prohibited technologies without
                     consciously or unconsciously, the exportation of line to Vietnam shall be banned and whole
                   responsibility shall be put on to Enterprise. When Inspector becomes aware of the prohibited
                    technologies, the inspection process should be withheld.



                 (7) Confirm whether technology of the line is being applied by at least 3 (three) manufacturers
                    of member countries of OECD.



                                                                                                        101
   106   107   108   109   110   111   112   113   114   115   116