Page 121 - Equipment Import Regulations of Viet Nam for K-V Investment Promotion
P. 121
Annex IV. Inspection Checklist: Used Machinery and Equipment
7. Remaining Capacity or Performance shall be checked additionally. (* For used machinery or equipment
only whose age exceeds the age limit prescribed in Article 9 of Decision 18)
Y N N/A
Has a production planning, in comprehensible form on specific environmental,
been established and managed in a given time period?
Is the production planning well maintained in accordance with the user’s targeted?
Is a production capacity or performance at least 85% of its
design capacity or performance?
8. The Amount of Raw Materials or Energy Consumed shall be checked additionally.
(* For used machinery or equipment only whose age exceeds the age limit
prescribed in Article 9 of Decision 18)
Y N N/A
Is the clamp meter used to check amperage, voltage, and resistance of each
operated equipment?
Is the clamp meter calibrated and well maintained by authorized personnel?
Is the electric power consumption calculated for that value of square voltage
divided by value of resistance?
Does electric power consumption exceed 15% of its designed power
consumption level?
Is the raw material input plan well designed to meet production goals?
Is the difference calculated between the designed and actual input of raw
material to produce goods? (Or) Is the input amounts of raw materials for
product production different from the design?
Does raw materials consumption exceed 15% of its designed consumption level?
111